Water Quality
River water quality from upstream to downstream
Question: where along the river does water quality start to drop, which parameters break the standard most often, and does the treatment plant make a difference?
Profile along the river
The horizontal axis is distance from the source. Pick a parameter; the dashed line marks the Class II limit. Points that break the limit are drawn as a cross.
Status against the standard
✓ meets the standard · ✗ exceeds the standard (mean of 4 sampling rounds)
Method
- Data: 6 points × 4 sampling rounds (February, May, August, November), processed with
analysis/02_olah_data.py. - Reference: Class II river water standard, Annex VI of Indonesian Government Regulation (PP) No. 22/2021 (pH 6–9; DO ≥ 4 mg/L; BOD ≤ 3 mg/L; COD ≤ 25 mg/L; TSS ≤ 50 mg/L). Check against the official document before using it in a report.
- Next step: compute the Pollution Index (IP) or the STORET method for a formal water quality status.